Instruments for Refrigeration and Cooling – Nivelco

Nivelco Process Instruments for Refrigeration and Cooling Process Updated October 11, 2014 with video Nivelco and MCE Process can provide all you instrumentation needs for refrigeration, ammonia cooling and related processes.   Get Quote The Nivelco Refrigeration and Cooling process diagram below illustrates a cooling technologic process commonly used in food, chemical and pharmaceutical industrial plants. On the process diagram can be seen the cooling compressor applying ammonia, the circulating pump system and the liquid separator tank with the proposed Nivelco devices. Nivelco Product Used Instrumentation of the compressor: The measurement of the pressure on the suction and pressure side is accomplished by NIPRESS DRC-3xxx type pressure transmitter The measurement of the temperature is completed by THERMOCONT TTJ-Sxxx temperature transmitters The suction side pressure transmitter performs the power control or the compressor, while the pressure side transmitter controls the condenser Instrumentation of the liquid-separator: The continuous level measurement is executed by NIVOCAP CTR-2xxx type capacitive level transmitter This device controls the feeding valve applying me UNICONT PMM-311 type controller The upper and lower failsafe switching is executed by NIVOMAG MKA-210 type level switches, As high level is reached, the compressor shuts off, while at low level the ammonium pump is stopped. Instrumentation of the liquid tank: The instruments and procedure is similar to the separator but a NIVOTRACK MTG or MTC-5xxx type level transmitter is recommended due to the high pressure (16 bar) Instrumentation of the cooling water: A continuous level measurement is accomplished with EchoTREK SGA-3xxx type ultrasonic level transmitter, the level in the tank is kept constant by the help of a UNICONT PMM-311 type controller by actuating a supplementary water valve The continuous conductance measurement is executed with an ANACONT LGK-2xxx type device, The conductivity or cooling water is permanently increasing due to the evaporation in the condenser, so at a predetermined value, the PMM-311 controller opens the emptying as well as the supplementary valve The low and high failsafe NIVOSWITCH RFM-401 type switches protect the pump and issue the alarm signals. Instrumentation of the condenser: The level control of the water tank under the…

Continue Reading

Nivelco Instruments for Wastewater Treatment

Wastewater Treatment Plant Instruments from Nivelco     Get A Quick Quote >> Nivelco and MCE Process can provide all your instrumentation and control needs for collection systems, liftstations and pumps, package plants and wastewater treatment plant. This diagram of the wastewater treatment process details two separate sections: wastewater treatment processes and slurry treatment processes. COLLECTION SYSTEM / LIFTSTATIONS / SUMPS / PITS The sewage is collected in lifstations, underground sumps or pits, also known as wetwells, and is pumped to the sewage treatment plant. Measurement and control tasks: Reliable level measurement is necessary to provide pump start and stop signals with fail safe switch-off points to avoid dry running. RECOMMENDED INSTRUMENTS The  EasyTREK SP type non-contact ultrasonic level transmitter models with IP68 ingress protection is Nivelco's recommendation for this measurement task. Another popular choice for liftstations or deep sumps is the flush mounted  NIVOPRESS NC  type hydrostatic borehole transmitter or the NIVOPRESS NP  series with recessed membrane equipped with a sewage adaptor working on the principal of the diving bell. A  PLC  or our  MultiCONT  process controller unit is ideal to process the analogue 4…20 mA signals and to control the switching points. For fail-safe protection, the robust NIVOFLOAT NWP float level switches are recommended. WASTEWATER TREATMENT PLANT The sewage pumped in from the network contains a lot of organic and non-organic materials in suspended form as well as in solution. This pollution has to be removed. The particles are filtered with a mechanical screen. The dissolved pollution can be reduced by adding coagulant materials. The reduced slurry is then separated from the water in the sedimentation tank. The purified sewage can be streamed to any natural water after chemical inspection and yield measurement. RECOMMENDED INSTRUMENTS Ultrasonic level transmitters for level measurement (2-wire integrated  (blind) or compact versions), EchoTREK or EasyTREK For the control of the mechanical screen a differential system with 2 ultrasonic level transmitters is recommended The  AnaCONT  range of analytical measurement devices is ideal for the chemical analysis of the cleaned water Open channel flow metering can be done using our  Parshall flume, and …

Continue Reading
Water Treatment Plant Instruments from Nivelco – Potable Water Production
Water Treatment Process

Water Treatment Plant Instruments from Nivelco – Potable Water Production

Nivelco Process Instruments for Water Treatment Plants - Potable Water Production Get A Quick Quote >> Nivelco and MCE Process can provide all your instrumentation needs for production wells, purification, treatment, and distribution system. PRODUCTION WELLS The production wells are drilled in ground layers rich in water, the pumps are lowered into the wells to pump the raw water to the central water treatment facilities. Measuring tasks: Continuous level measurement of the well Temperature measurement of the water Hydrostatic pressure (water level) of the production well Flow of the produced water Dry-run protection of the pumps RECOMMENDED INSTRUMENTS Hydrostatic level transmitters that combine level and temperature measurement: the NIVOPRESS N transmitter family. Piezoresistive pressure transmitters: NIVOPRESS NZK types Water input measurement: ISOMAG electro-magnetic flow meters WATER TREATMENT PLANT The raw water pumped from the production wells contains different organic and inorganic materials. These materials have to be removed from the water. Removal is done either by mechanical filters or by adding coagulant materials to the water to help precipitate the contaminating materials. The resulting slurry is separated in settling tanks. The clean water is often passed through sand or other final filtration stages. RECOMMENDED INSTRUMENTS Pressure measurement with  NIPRESS type pressure transmitters Level measurement with EchoTREK ultrasonic level transmitters pH measurement of the clean water with AnaCONT analytical instruments Low/high level switching with NIVOSWITCH or NIVOMAG level switches Turbidity measurement with 28053 US EPA 180.1 Turbidimeter Turbidity measurement with 28052 ISO 7027 Turbidimeter WATER DISTRIBUTION SYSTEM To move water out to the distribution system and to the customers, the pressure in the system has to be increased. This is done by booster pumps, water towers or air charged pressure vessels with compressed-air pumps. RECOMMENDED INSTRUMENTS Pressure control at the compressed-air pumps with  NIPRESS pressure transmitters and UNICONT controllers Water level control at the compressed-air pumps with  NIVOCAP level transmitters and UNICONT controllers Water level measurement in the reservoir or watertower with  EasyTREK ultrasonic level transmitters from either the top or the bottom of the water tower with NIVOPRESS D type hydrostatic level transmitters

Continue Reading
Close Menu
Quick Quote

 

 

  • (required)
  • (required)
  • This field is for validation purposes and should be left unchanged.
×
Product Quote
×
Partner Link from Page

Share & Make Money – MCE Partner Program

You must be an active Partner and Logged In.

×
  • Please tell us your target price, best offer or lowest price found for this item.
  • Accepted file types: jpg, gif, png, pdf, doc, docx, xls, xlsx.
  • This field is for validation purposes and should be left unchanged.
×
  • Accepted file types: jpg, png, pdf.
    Upload or Take a Picture on Your Phone / Device
  • OPTIONAL: Enter email here if you would like a reward for your photo. Your email stays private with us and will never be shared.
  • This field is for validation purposes and should be left unchanged.
×
  • Stories posted on our site will receive a bounty / store credit. The best stories with good pictures earn up to $150 bounty / store credit.
  • Enter your email here if you would like a reward for your photo / application story. Your email stays private with us and will never be shared.
  • A short description of your application or problem solved with the product.
  • Accepted file types: jpg, png, pdf, doc, docx.
    Optional: Upload File or Take a Picture on Your Phone / Device
  • This field is for validation purposes and should be left unchanged.
×
×
×

Cart